In many locations from chemistry laboratories to industrial facilities, so as to ensure the safety of life and property towards a potential fire hazard, extinguishing systems are used in addition to detection and alarm techniques. It can be extremely necessary that the extinguishing methods put in could be triggered by the fireplace extinguishing control panel, so as to eliminate a attainable hearth with early intervention.
In order to satisfy these wants, and with 35 years of sectoral information and experience, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant performance of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be started manually and remotely; and
to make certain that the extinguishing course of can be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced utilizing surface-mount know-how and are aimed at making the automation of the extinguishing system and fire and gas detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times considering the needs of the set up. In circumstances that require the integration of the extinguishing system with the clever addressable fireplace detection system, it provides options through the monitoring modules that also have a ‘supervised’ possibility.
Supervised monitoring modules play an important position in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or brief circuit within the wiring between the contact monitoring modules and the peripheral systems could cause disruption of the triggering, with probably crucial penalties. For เกจวัดแรงดันน้ำดิจิตอล , when choosing monitoring modules, it must be taken into consideration that they have supervised options.
Image copyright: Mavili
Since Maxlogic intelligent addressable fireplace detection and alarm management panels are continuously communicating with ‘supervise’ contact monitoring modules connected to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it easier to observe situations corresponding to open circuits and brief circuits which will occur in the system. Many tasks could be performed within the hearth extinguishing installation, such because the control and monitoring of all valves that may interrupt the move of water, water move alarm switches, strain change, and electric or diesel hearth pumps.
By adding two contact monitoring modules to two separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to control errors and the opposite to manage the fireplace state of affairs, monitoring and control of the extinguishing system by way of an intelligent addressable fire detection and alarm system can be performed effectively.
For extra information, go to www.mavili.com.tr/en
Share

Leave a Reply